Various fixing screws and fittings.
Plus the following essential items:-
A) Water Speader & Adaptor - 1 off
B) Injector Tee - 1 off
C) Restrictor Ring -1 off
These items must be fitted in accordance with the instructions contained within the booklet.
Please leave these instructions adjacent to the gas meter.
PW3 Deluxe GC No. 37 077 21
C3 GC No. 37 077 10
W3 GC No. 37 077 14
GF Super GC. No. 37 077 15
LFE3 Super GC No. 37 077 16
VP GC No. 37 077 17
SP GC No. 37 077 18
C3W GC No. 37 077 20
SL GC No. 37 077 26
RG GC No. 37 077 30
GAS FIRE | VERTICAL FLAT AREA | |
MINIMUM DIMENSIONS | ||
HEIGHT | WIDTH | |
VP | 765mm (30 1/8in) | 765mm (30 1/8in) |
B | 675mm (26 5/8in) | 765mm (30 1/8in) |
C3 | 660mm (26in) | 920mm (36 1/4in) |
C3W | 675mm (26 5/8in) | 920mm (36 1/4in) |
G.F. Super/SL | 765mm (30 1/8in) | 765mm (30 1/8in) |
LFE3 Super | 789mm (31in) | 998mm (39 5/16in) |
W3 | 700mm (27 1/2in) | 1200mm (47 1/4in) |
SP | 765mm (30 1/8in) | 765mm (30 1/8in) |
PW3 Deluxe | 660mm (26in) | 1010mm (39 3/4in) |
RG | 810mm (31 7/8in) | 800mm (31 1/2in) |
SURROUND OPENING ALL FIRES | ||
HEIGHT | 560 mm (22in) | |
MINIMUM DIMENSION | MAXIMUM DIMENSION | |
WIDTH Jabra app for mac. Jabra works with leading monitoring partners to make the management of your Jabra headsets simpler and smarter. Micro apps for PC. Jabra now brings easy-to-use Windows software micro applications to extend the value of Jabra audio devices and anticipate users’ needs. Software & services. Jabra Suite for Mac will no longer be updated but can still be used. New updates for Jabra products will only be released in Jabra Direct version 4.x or later. New Jabra products will only be present in Jabra Direct version 4.x or later. Multiple versions of Jabra Direct cannot be installed and used simultaneously. | 406 mm (16in) | 584 mm (23in) |
508 mm.(20in)
SP & VP=ONLY
BOILER DIMENSIONS | ||
From Back of Boiler | From Hearth Level | |
A | 328 mm (12 15/16in) | - |
B | 82 mm (3 7/16in) | - |
C | - | 401 mm (16in) |
D | - | 504 mm (20in) |
E | - | 529 mm (20 15/16in) |
F | 343 mm (13 1/2in) | - |
G | 390 mm (15 3/8in) | - |
FLOW AND RETURN TAPPINGS | |||
From Back of Boiler-When on | From Hearth | ||
Left Hand | Right Hand | Level | |
H Rear Flow | 71 mm (2 13/16in) | 99 mm (3 7/8in) | 333 mm (13 1/8in) |
I Front Flow | 158 mm (6 1/4in) | 186 mm (7 5/16in) | 333 mm (13 1/8in) |
J Return | 100 mm (3 15/16in) | 158 mm (6 1/4in) | 241 mm (9 1/2in) |
Baxi Thermostat Instruction Manual Instructions
Connect the pumped flow to the top front tapping for left hand connections or the top rear tapping for right hand connections.
Heat Input | 21.2 kW (72,400 Btu/h) | 17.0 kW (58,000 Btu/h) | 13.2 kW (45,000 Btu/h) |
Heat Output | 16.1 kW (55,000 Btu/h) | 12.8 kW (43,300 Btu/h) | 10.0 kW (34,000 Btu/h) |
Natural Gas | 17 mbar (6.8in w.g.) | 11.0 mbar (4.4in w.g.) | 6.7 mbar (2.8in w g.) |
1in diameter x 2 1/2in long bristle brush.
User Manual
ITEM | BAXI CODE NO. |
Boiler Injector | 043175 |
Pilot Injector | 082212 |
Pilot Connector Reducer | 082215 |
Gas Valve- Honeywell V4600D | 043077 |
Key Number | G.C. Number | Description | Makers Part Number |